Stangenes Current Transformers have been constructed in so many shapes and sizes that it is impossible to show them all at once. The following descriptions represent broad categories, which can be reconfigured almost infinitely.

For measurement of pulse and AC currents over a wide range of amplitudes, pulse lengths, and frequencies.

Stangenes Current Transformers have:
  • Complete isolation from the circuit to be measured (no ground currents)
  • Shielded construction
  • Internal 50 ohm termination for coaxial cable matching
  • High accuracy (±0.5%)
  • A variety of hole sizes to fit most conductors and voltages
Other standard and custom models available.
1 - 15 of 15 | Results Per Page | View | Unit of Measure
1 

Item #

Output
(Accuracy ±0.5%)

Inner
Diameter

Max. Current
(Peak)

Max. Current
(RMS)

Pulse
Rise Time

Sort by
N/A 1 (volt/amp) N/A 3.5 in N/A 500 A N/A 7 A N/A 50 ns
N/A 1 (volt/amp) N/A 2.87 in N/A 500 A N/A 7 A N/A 20 ns
N/A 1 (volt/amp) N/A 2 in N/A 500 A N/A 7 A N/A 20 ns
N/A 1 (volt/amp) N/A 1 in N/A 500 A N/A 7 A N/A 20 ns
N/A 1 (volt/amp) N/A 0.5 in N/A 500 A N/A 7 A N/A 10 ns
N/A 0.01 (volt/amp) N/A 3.5 in N/A 50 k A N/A 400 A N/A 200 ns
N/A 0.01 (volt/amp) N/A 2.87 in N/A 50 k A N/A 100 A N/A 20 ns
N/A 0.01 (volt/amp) N/A 0.5 in N/A 50 k A N/A 100 A N/A 20 ns
N/A 0.1 (volt/amp) N/A 3.5 in N/A 5 k A N/A 70 A N/A 50 ns
N/A 0.1 (volt/amp) N/A 2.87 in N/A 5 k A N/A 30 A N/A 20 ns
N/A 0.1 (volt/amp) N/A 2.87 in N/A 5 k A N/A 30 A N/A 20 ns
N/A 0.1 (volt/amp) N/A 2 in N/A 5 k A N/A 30 A N/A 20 ns
N/A 0.1 (volt/amp) N/A 1 in N/A 5 k A N/A 30 A N/A 20 ns
N/A 0.1 (volt/amp) N/A 0.5 in N/A 5 k A N/A 30 A N/A 10 ns
N/A 0.002 (volt/amp) N/A 2.87 in N/A 200 k A N/A 1100 A N/A 100 ns
1 - 15 of 15 | Results Per Page | View | Unit of Measure